Fluke 9100S-A-156 Dry Block Calibrator with block A, 95 to 707?F
USD 16,785.47 Original price was: USD 16,785.47.USD 10,071.28Current price is: USD 10,071.28.
- Size Guide
Size Guide
BatteriesUPSAVSInverterBatteriesVOLTS AMPS HOUR AMPS HOUR AMPS HOUR 6 1.2 5 35 12 2.3 7 55 24 2.8 9 65 48 2.9 12 100 3.2 18 100 3.5 26 200 4.5 33 240 The measurements are in Voltage UPSType of Phase RATING (VA) RATING (KVA) RATING (KVA) 1 : 1 450 1 40 1 : 1 | 3 : 1 500 2 60 3 : 1 650 3 80 3 : 3 750 5 100 800 6 120 1000 10 160 1500 15 200 2000 20 250 3000 30 300 The measurements are in Voltage Volt-ampere (VA) and Kilo-volt-amperes (KVA) AVSType of Phase RATING (KVA) RATING (KVA) RATING (VA) Single Phase 1 30 300 Three Phase 2 45 400 3.5 60 500 5 75 600 7.5 100 800 10 120 1000 15 150 1500 22.5 200 2000 25 250 3000 The measurements are in Voltage and Kilo-volt-amperes (KVA) InverterType of Phase RATING (VA) RATING (KVA) RATING (KVA) Single Phase 350 1 15 Three Phase 500 2 20 1000 3 30 1500 5 40 2000 6 60 3000 10 80 15 100 The measurements are in Voltage Volt-ampere (VA) and Kilo-volt-amperes (KVA) - Delivery & Return
Delivery
Store Pickup FREE
Allow 1-3 working days for Items in stock.
6-8 working weeks for items that are Out of Stock
Delivery Charge
All Items are subject to Transport / Delivery Charge
Returns
Return
We do not accept returns or exchanges. A 40% restocking fee will be charged for returned items.
Returns in store
Your return will usually be processed within a week to a week and a half. We’ll send you a Return Notification email to notify you once the return has been completed. Please allow 1-3 business days for refunds to be received to the original form of payment once the return has been processed.
- Ask a Question
Description
Fluke 9100S-A-156 OffersBy using a precision platinum RTD as a sensor, well temperature is controlled with a Triac-driven heater. Small enough to use in the field and accurate enough to use in the lab, the unit functions equally well as a portable instrument or benchtop temperature calibrator for calibrating thermocouple and RTD temperature probes.
Within a range of 95 to 707°F (35 to 375°C ), this unit provides continuous accurate calibration of temperature sensors and devices. With a proprietary Fluke Calibration temperature controller, the dry well has a display resolution of 0.1 degrees, an accuracy of ±0.5°C, stability of ±0.1°C, and a stabilization time of just five minutes.
Features
Compact design
Ranges from 95 to 707°F (35 to 375°C)
Accuracy to ±0.25°C, stability of ±0.25°C at 50°C
RS-232 interface with 9930 Interface-it v3.81 software
Rapid heating and cooling
Prop stand
Temperature scan rate control
Eight set-point memory
Adjustable readout in °C or °FFluke 9100S-A-156 OffersBy using a precision platinum RTD as a sensor, well temperature is controlled with a Triac-driven heater. Small enough to use in the field and accurate enough to use in the lab, the unit functions equally well as a portable instrument or benchtop temperature calibrator for calibrating thermocouple and RTD temperature probes.
Within a range of 95 to 707°F (35 to 375°C ), this unit provides continuous accurate calibration of temperature sensors and devices. With a proprietary Fluke Calibration temperature controller, the dry well has a display resolution of 0.1 degrees, an accuracy of ±0.5°C, stability of ±0.1°C, and a stabilization time of just five minutes.
Features
Compact design
Ranges from 95 to 707°F (35 to 375°C)
Accuracy to ±0.25°C, stability of ±0.25°C at 50°C
RS-232 interface with 9930 Interface-it v3.81 software
Rapid heating and cooling
Prop stand
Temperature scan rate control
Eight set-point memory
Adjustable readout in °C or °F
Fluke 9100S-A-156 Specifications
Range
95 to 707°F (35 to 375°C)
Accuracy
±0.25°C at 50°C
±0.25°C at 100°C
±0.5°C at 375°C
Stability
±0.07°C at 50°C
±0.1°C at 100°C
±0.3°C at 375°C
Resolution
0.1°C or °F
Well-to-Well Uniformity
±0.2°C with sensors of similar size at equal depths within wells
Computer Interface
RS-232 included with Interface-It software
NIST-Traceable Calibration
Data at 122°F (50°C), 212°F (100°C), 302°F (150°C), 392°F (200°C), 482°F (250°C), 572°F (300°C), and 707°F (375°C)
Heating Times
95 to 707°F (35 to 375°C): 9.5 minutes
Stabilization
5 minutes
Cooling Times
707 to 212°F (375 to 100°C): 14 minutes
Well Depth
4″ (102 mm)
1⁄16″ (1.6 mm) hole in 3.5″ (89 mm) deep
Power
115 V AC (±10%), 55 to 65 Hz, 1.5 A or 230 V AC (±10%), 0.8 A, 45 to 55 Hz, 175 W
Dimensions
2.25 x 4.9 x 6.1″ (57 x 125 x 150 mm)
Weight
2 lbs (1 kg)
What’s included with the Fluke 9100S-A-156
Dry Well
NIST-Traceable Calibration
Software
Power Cord
Serial Cable
User’s Guide
Webinar: Temperature Calibrations with Fluke
We understand the importance of the performance of temperature and pressure instruments in your business as often being critical when trying to optimize operations, product quality or to ensure proper functioning of safety systems. As such, we’ve teamed up with Fluke to offer you a series of two webinars on this topic. The first will provide valuable information to help you identify temperature calibration improvements in your business. The second will focus on identifying pressure calibration improvements.
Let’s start with Temperature Calibrations… This valuable one-hour Fluke seminar will give you the knowledge to quickly identify improvements to your temperature calibrations and associated workflows. Providing you with key insights when reviewing your temperature calibration workload and highlights the latest “best practices”, methods and tools that will allow you to maximize results when testing the most common temperature instruments.
During this 1-hour webinar, we’ve covered:
• Temperature calibration – an overview and review
• Workload and applications checklist
• Identify, isolate and eliminate common sources of error
• Best practices and tech tips
• Using technology for workflow improvements
• How to maximize your results
Additional information
Weight | 1 kg |
---|---|
Dimensions | 5.7 × 12.5 × 15 cm |
Model | 9100S-A-156 |
PRODUCT TYPE | Process Calibration Tools |
Brand | FLUKE |
Warranty | 12Months Warranty against manufacturers defects |
Country of Origin | USA |