Fluke 721-3601 Dual Sensor Pressure Calibrator
USD 19,951.32 Original price was: USD 19,951.32.USD 11,970.79Current price is: USD 11,970.79.
- Size Guide
Size Guide
BatteriesUPSAVSInverterBatteriesVOLTS AMPS HOUR AMPS HOUR AMPS HOUR 6 1.2 5 35 12 2.3 7 55 24 2.8 9 65 48 2.9 12 100 3.2 18 100 3.5 26 200 4.5 33 240 The measurements are in Voltage UPSType of Phase RATING (VA) RATING (KVA) RATING (KVA) 1 : 1 450 1 40 1 : 1 | 3 : 1 500 2 60 3 : 1 650 3 80 3 : 3 750 5 100 800 6 120 1000 10 160 1500 15 200 2000 20 250 3000 30 300 The measurements are in Voltage Volt-ampere (VA) and Kilo-volt-amperes (KVA) AVSType of Phase RATING (KVA) RATING (KVA) RATING (VA) Single Phase 1 30 300 Three Phase 2 45 400 3.5 60 500 5 75 600 7.5 100 800 10 120 1000 15 150 1500 22.5 200 2000 25 250 3000 The measurements are in Voltage and Kilo-volt-amperes (KVA) InverterType of Phase RATING (VA) RATING (KVA) RATING (KVA) Single Phase 350 1 15 Three Phase 500 2 20 1000 3 30 1500 5 40 2000 6 60 3000 10 80 15 100 The measurements are in Voltage Volt-ampere (VA) and Kilo-volt-amperes (KVA) - Delivery & Return
Delivery
Store Pickup FREE
Allow 1-3 working days for Items in stock.
6-8 working weeks for items that are Out of Stock
Delivery Charge
All Items are subject to Transport / Delivery Charge
Returns
Return
We do not accept returns or exchanges. A 40% restocking fee will be charged for returned items.
Returns in store
Your return will usually be processed within a week to a week and a half. We’ll send you a Return Notification email to notify you once the return has been completed. Please allow 1-3 business days for refunds to be received to the original form of payment once the return has been processed.
- Ask a Question
Description
Fluke 721-3601 Offers
Features
Two isolated, stainless steel, pressure sensors with 0.025% f.s. accuracy
Can be configured by selecting either a 16 psig (1.1 bar) or 36 psig (2.48 bar) low pressure sensor and then adding your choice of 7 high pressure ranges
External pressure module connection supports all pressure modules (29 ranges) for even more measurement capability
Temperature-compensation ensures accuracy in field applications
Pt100 RTD input for temperature measurement, accurate to 0.1°C (0.2°F) (Requires optional RTD probe sold separately)
Measure 4-20 mA signals
Internal 24 V Loop Power Supply can power a transmitter under test
Measure up to 30 V DC
Large graphic style LCD with backlight can be configured to display up to 3 inputs simultaneously (i.e. pressure 1, pressure 2, and RTD or any combination of inputs)
Pressure displayed in the user’s choice of 19 engineering units
Switch test on both pressure inputs, or external pressure module
Operating mode layers support simple measurements to complex applications
Up to five frequently used setups can be stored; last setup automatically recalled on power-up
% error and damping functions
Application Selection Guide
Model number
754
721/721Ex
719Pro
719
718
717
700G
3130
2700G
Dead-weight Testers
Application
Calibrating pressure transmitters (field)
●
●
Ideal
●
●
●
●
Calibrating pressure transmitters (bench)
●
●
●
●
●
●
Ideal
●
Calibrating HART Smart transmitters
Ideal
Documenting pressure transmitter calibrations
Ideal
Testing pressure switches in the field
Ideal
●
●
●
●
●
●
Testing pressure switches on the bench
●
●
●
●
●
●
Ideal
Documenting pressure switch tests
Ideal
Testing pressure switches with live (voltage) contacts
Ideal
Gas custody transfer computer tests
●
Ideal
●
Verifying process pressure gauges (field)
Ideal
●
●
●
●
●
●
Verifying process pressure gauges (bench)
●
●
●
●
●
●
●
●
Ideal
Logging pressure measurements
●
Ideal
●
Testing pressure devices using a reference gauge
Ideal
Hydrostatic vessel testing
Ideal
Leak testing (pressure measurement logging)
●
Ideal
Pressure Calibration Selection GuideFluke 721-3601 Offers
Features
Two isolated, stainless steel, pressure sensors with 0.025% f.s. accuracy
Can be configured by selecting either a 16 psig (1.1 bar) or 36 psig (2.48 bar) low pressure sensor and then adding your choice of 7 high pressure ranges
External pressure module connection supports all pressure modules (29 ranges) for even more measurement capability
Temperature-compensation ensures accuracy in field applications
Pt100 RTD input for temperature measurement, accurate to 0.1°C (0.2°F) (Requires optional RTD probe sold separately)
Measure 4-20 mA signals
Internal 24 V Loop Power Supply can power a transmitter under test
Measure up to 30 V DC
Large graphic style LCD with backlight can be configured to display up to 3 inputs simultaneously (i.e. pressure 1, pressure 2, and RTD or any combination of inputs)
Pressure displayed in the user’s choice of 19 engineering units
Switch test on both pressure inputs, or external pressure module
Operating mode layers support simple measurements to complex applications
Up to five frequently used setups can be stored; last setup automatically recalled on power-up
% error and damping functions
Application Selection Guide
Model number
754
721/721Ex
719Pro
719
718
717
700G
3130
2700G
Dead-weight Testers
Application
Calibrating pressure transmitters (field)
●
●
Ideal
●
●
●
●
Calibrating pressure transmitters (bench)
●
●
●
●
●
●
Ideal
●
Calibrating HART Smart transmitters
Ideal
Documenting pressure transmitter calibrations
Ideal
Testing pressure switches in the field
Ideal
●
●
●
●
●
●
Testing pressure switches on the bench
●
●
●
●
●
●
Ideal
Documenting pressure switch tests
Ideal
Testing pressure switches with live (voltage) contacts
Ideal
Gas custody transfer computer tests
●
Ideal
●
Verifying process pressure gauges (field)
Ideal
●
●
●
●
●
●
Verifying process pressure gauges (bench)
●
●
●
●
●
●
●
●
Ideal
Logging pressure measurements
●
Ideal
●
Testing pressure devices using a reference gauge
Ideal
Hydrostatic vessel testing
Ideal
Leak testing (pressure measurement logging)
●
Ideal
Pressure Calibration Selection Guide
Fluke 721-3601 Specifications
Specifications 1-Year
Low pressure sensor
Range
Resolution
Accuracy
-14 psi to +16 psi,
-0.97 bar to 2.48 bar
0.001 psi,
0.0001 bar
0.025 % of full scale
High pressure sensor
-12 psi to +100 psi,
-0.83 bar to 6.9 bar
0.01 psi,
0.0001 bar
0.025 % of full scale
General Specifications
Instrument setup recall
Last used on power-up
Environmental
Operating temperature -10 °C to +50 °C
Storage temperature (without batteries) -20 °C to +60 °C
Altitude
2,000 meters
Ingress protection
IP-40
Power requirements
6.0 v dc
Battery life
>35 hours, typical usage
Batteries required
(4) Standard AA cells
Dimentions (HxWxD)
7.9″ X 4.3″ X 2.3″ (20 cm X 11 cm X 5.8 cm)
Weight
03539 kg (1 lb 3 oz)
Connectors/ports pressure
Two, 1/8 in NPT, 700P Series Pressure Module; RTD Probe
Electrical and Temperature Measurement 1-Year
Function
Range
Resolution
Accuracy
mA measure
0 to 24 mA
0.001 mA
±0.015% of rdg
±0.002mA
VDC measure
0 to 30 VDC
0.001V
±0.015% of rdg
±0.002V
*Temperature measure (RTD/ Ohms)
-40 °C to 150 °C
(-40 °F to 302 °F)
0.01 °C, 0.01 °F
±0.015% of rdg
±0.02 ohms
±0.1°C (±0.2°F)
±0.25 degC (±0.45
degF) combined uncertainty when using 720 RTD probe accessory
Loop power supply
24V
N/A
24 mA @ 24V
*Temperature measurement requires optional Fluke-720RTD Pt-100 RTD probe available as an accessory
Temperature Effect
No effect on accuracy on all functions from 15 °C to 35 °C
Add ± 0.002 % F.S./°C for temps outside of 15 °C to 35 °C
Available Pressure Engineering Units
psi, bar, mbar, kPa, kgcm2, cmH2O@4°C, cmH2O@20°C, mH2O@4°C, mH2O@20°C, inH2O@4°C, inH2O@20°C, inH2O@60°F, mmHg@0°C, inHg@0°C, ftH2O@4°C, ftH2O@20°C, ftH2O@60°F
What’s Included with the Fluke 721 Series
Dual Sensor Pressure Calibrator
Soft case
Four (4) AA batteries
Manual
Traceable calibration certificate
Test leads
Additional information
Weight | 3539 kg |
---|---|
Dimensions | 20 × 11 × 5.8 cm |
Model | 721-3601 |
PRODUCT TYPE | Pressure Calibrators |
Brand | FLUKE |
Warranty | 12Months Warranty against manufacturers defects |
Country of Origin | USA |