Fluke 572-2 High Temperature Infrared (IR) Thermometer, -22 to 1652?F
USD 7,092.76 Original price was: USD 7,092.76.USD 4,255.65Current price is: USD 4,255.65.
- Size Guide
Size Guide
BatteriesUPSAVSInverterBatteriesVOLTS AMPSÂ HOUR AMPSÂ HOUR AMPSÂ HOUR 6 1.2 5 35 12 2.3 7 55 24 2.8 9 65 48 2.9 12 100 Â 3.2 18 100 Â 3.5 26 200 Â 4.5 33 240 The measurements are in Voltage UPSType of Phase RATING (VA) RATING (KVA) RATING (KVA) 1 : 1Â 450 1 40 1 : 1 | 3 : 1 500 2 60 3 : 1 650 3 80 3 : 3 750 5 100 Â 800 6 120 Â 1000 10 160 Â 1500 15 200 Â 2000 20 250 Â 3000 30 300 The measurements are in Voltage Volt-ampere (VA) and Kilo-volt-amperes (KVA) AVSType of Phase RATING (KVA) RATING (KVA) RATING (VA) Single Phase 1 30 300 Three Phase 2 45 400 Â 3.5 60 500 Â 5 75 600 Â 7.5 100 800 Â 10 120 1000 Â 15 150 1500 Â 22.5 200 2000 Â 25 250 3000 The measurements are in Voltage and Kilo-volt-amperes (KVA) InverterType of Phase RATING (VA) RATING (KVA) RATING (KVA) Single Phase 350 1 15 Three Phase 500 2 20 Â 1000 3 30 Â 1500 5 40 Â 2000 6 60 Â 3000 10 80 Â Â 15 100 The measurements are in Voltage Volt-ampere (VA) and Kilo-volt-amperes (KVA) - Delivery & Return
Delivery
Store Pickup FREE
Allow 1-3 working days for Items in stock.
6-8 working weeks for items that are Out of Stock
Delivery Charge
All Items are subject to Transport / Delivery Charge
Returns
Return
We do not accept returns or exchanges. A 40% restocking fee will be charged for returned items.
Returns in store
Your return will usually be processed within a week to a week and a half. We’ll send you a Return Notification email to notify you once the return has been completed. Please allow 1-3 business days for refunds to be received to the original form of payment once the return has been processed.
- Ask a Question
Description
Fluke 572-2 OffersThis high-temperature infrared thermometer is built for use in high-temperature industrial environments. It has a straight-forward user interface and soft-key menus, making even complex measurements easier. Quickly navigate and adjust emissivity, start data logging, or turn on and off alarms, with just a few pushes of a button.
Features
60:1 distance to spot ratio with dual laser sighting for fast, accurate targeting
Multi-language interface (user select)
Current Temperature plus MAX, MIN, DIF, AVG temperature displays
Compatible with standard mini-connector K-type thermocouples
Adjustable emissivity and predefined emissivity table
Infrared and thermocouple temperature on backlit display
Last reading Hold (20 seconds)
High and low temperature alarm
Data storage and review (99 data sets)
Tripod mount
12 or 24 hour clock
USB 2.0 computer interface cable
FlukeView® Forms Documenting Software
Two-year warranty
Applications
Utilities
Mining and Minerals
Oil and GasFluke 572-2 OffersThis high-temperature infrared thermometer is built for use in high-temperature industrial environments. It has a straight-forward user interface and soft-key menus, making even complex measurements easier. Quickly navigate and adjust emissivity, start data logging, or turn on and off alarms, with just a few pushes of a button.
Features
60:1 distance to spot ratio with dual laser sighting for fast, accurate targeting
Multi-language interface (user select)
Current Temperature plus MAX, MIN, DIF, AVG temperature displays
Compatible with standard mini-connector K-type thermocouples
Adjustable emissivity and predefined emissivity table
Infrared and thermocouple temperature on backlit display
Last reading Hold (20 seconds)
High and low temperature alarm
Data storage and review (99 data sets)
Tripod mount
12 or 24 hour clock
USB 2.0 computer interface cable
FlukeView® Forms Documenting Software
Two-year warranty
Applications
Utilities
Mining and Minerals
Oil and Gas
Fluke 572-2 Specifications
Infrared Measurements
Temperature Range
-22 to 1652°F (-30 to 900°C)
IR Accuracy (calibration geometry with ambient temperature 23°C ±2°C)
≥32°F: ±2°F or ±1% of the reading, whichever is greater
≥14°F to <32°F: ±4°F <14°F: ±6°F ≥0°C: ±1°C or ±1 % of the reading, whichever is greater ≥-10°C to <0°C: ±2°C <-10°C:±3 °C IR Repeatability ±0.5% of reading or ±1°F (±0.5°C), whichever is greater Display Resolution 0.1°F/0.1°C Distance:Spot 60:1 (calculated at 90% energy) Minimum Spot Size 0.75" (19 mm) Laser Sighting Offset dual laser, output <1 mW Spectral Response 8 µm to 14 µm Response Time (95%) <500 ms Emissivity Digitally adjustable from 0.10 to 1.00 by 0.01 or via built-in table of common materials Contact Measurements K-Type Thermocouple Input Temperature Range -454 to 2501°F (-270 to 1372°C) K-Type Thermocouple Input Accuracy <-40°F: ±(2°F + 0.2°/1°F) ≥-40°F: ±1% or 2°F, whichever is greater <-40°C: ±(1 °C + 0.2°/1°C) ≥-40°C: ±1% or 1°C, whichever is greater K-Type Thermocouple 0.1°F/0.1°C K-Type Thermocouple Repeatability ±0.5% of reading or ±1°F (±0.5°C), whichever is greater Measurement Options Hi/Low Alarms Audible and two-color visual Min/Max/Avg/Dif Yes Switchable Celsius and Fahrenheit Yes Backlight Two levels, normal and extra bright for darker environments Probe Input K-type thermocouple simultaneous display of probe and IR temperature Trigger Lock Yes Data Storage 99 points Display Dot matrix 98 x 96 pixels with function menus Communication USB 2.0 K-Type Thermocouple Specifications Measurement Range (Bead Probe) -40 to 500°F (-40 to 260°C) Accuracy ±2.0°F (±1.1°C) from 32 to 500°F (0 to 260°C) Typically within 2.0°F (1.1°C) from -40 to 32°F (-40 to 0°C) Cable Length 40" (1 m) K-type thermocouple cable with standard miniature thermocouple connector and bead termination General Specifications Safety and Compliance IEC 60825-1 FDA Laser Class II IEC 61326-1 CE Complaint CMC # 01120009 Operating Temperature 32 to 122°F (0 to 50°C) Storage Temperature -4 to 140°F (-20 to 60°C) Relative Humidity 10 to 90% RH non-condensing up to 86°F (30°C) Operating Altitude 2000 meters above mean sea level Weight 0.7099 lb (0.322 kg) Power 2 x AA batteries Battery Life 8 hours with laser and backlight on; 100 hours with laser and backlight off, at 100 % duty cycle (thermometer continuously on) Click here for complete specifications on the Fluke 572-2 What's included with the Fluke 572-2 High Temperature Infrared Thermometer K-Type Thermocouple Bead Probe USB 2.0 Computer Interface Cable FlukeView Forms Documenting Software Hard Carrying Case Getting Started Guide User's Manual
Additional information
Weight | 0.322 kg |
---|---|
Dimensions | 28 × 28 × 25.4 cm |
Model | 572-2 |
PRODUCT TYPE | Infrared Thermometers |
Brand | FLUKE |
Warranty | 12Months Warranty against manufacturers defects |
Country of Origin | USA |