Fluke 1586A/1DS Super-DAQ Precision Temperature Scanner with DAQ-STAQ multiplexer
USD 38,921.02 Original price was: USD 38,921.02.USD 23,352.61Current price is: USD 23,352.61.
Ships in 5 -10days
- Size Guide
Size Guide
BatteriesUPSAVSInverterBatteriesVOLTS AMPSÂ HOUR AMPSÂ HOUR AMPSÂ HOUR 6 1.2 5 35 12 2.3 7 55 24 2.8 9 65 48 2.9 12 100 Â 3.2 18 100 Â 3.5 26 200 Â 4.5 33 240 The measurements are in Voltage UPSType of Phase RATING (VA) RATING (KVA) RATING (KVA) 1 : 1Â 450 1 40 1 : 1 | 3 : 1 500 2 60 3 : 1 650 3 80 3 : 3 750 5 100 Â 800 6 120 Â 1000 10 160 Â 1500 15 200 Â 2000 20 250 Â 3000 30 300 The measurements are in Voltage Volt-ampere (VA) and Kilo-volt-amperes (KVA) AVSType of Phase RATING (KVA) RATING (KVA) RATING (VA) Single Phase 1 30 300 Three Phase 2 45 400 Â 3.5 60 500 Â 5 75 600 Â 7.5 100 800 Â 10 120 1000 Â 15 150 1500 Â 22.5 200 2000 Â 25 250 3000 The measurements are in Voltage and Kilo-volt-amperes (KVA) InverterType of Phase RATING (VA) RATING (KVA) RATING (KVA) Single Phase 350 1 15 Three Phase 500 2 20 Â 1000 3 30 Â 1500 5 40 Â 2000 6 60 Â 3000 10 80 Â Â 15 100 The measurements are in Voltage Volt-ampere (VA) and Kilo-volt-amperes (KVA) - Delivery & Return
Delivery
Store Pickup FREE
Allow 1-3 working days for Items in stock.
6-8 working weeks for items that are Out of Stock
Delivery Charge
All Items are subject to Transport / Delivery Charge
Returns
Return
We do not accept returns or exchanges. A 40% restocking fee will be charged for returned items.
Returns in store
Your return will usually be processed within a week to a week and a half. We’ll send you a Return Notification email to notify you once the return has been completed. Please allow 1-3 business days for refunds to be received to the original form of payment once the return has been processed.
- Ask a Question
Description
Fluke 1586A/1DS OffersCollects time-stamped precision temperature and electrical measurements for data analysis by technicians, engineers, and quality control personnel to verify process control, analyze interactive systems, ensure conformance to quality standards, or to correlate related events for R&D or troubleshooting. Measurement data and statistics can be viewed in tabular format for all active channels. With the graphing feature, up to four channels can be plotted at the same time, making it easy to quickly assess test setup and results before analyzing the data on a PC.
Features
Best temperature measurement accuracy
Flexible configuration for the factory or bench-top
Real-time graphing in color
Data portability and security
Automated sensor calibration
Measure thermocouples, PRTs, thermistors, DC voltage, DC current, and resistance
Input channels: Up to 40 isolated universal inputs
Selectable scan speed: Up to 10 channels per second
Four modes of operation: Scan, Monitor, Measure, Digital Multimeter DMM)
Real-time color trending: Chart up to four channels simultaneously
6 1/2 digit display resolution for DC voltage, DC current, and resistance
Current reversal minimizes thermoelectric effects, improving PRT/RTD measurement accuracy
Automated sensor calibration: Control Fluke Calibration temperature sources such as dry-wells or micro-baths for automated calibration routines
Data storage: Records up to 20 MB of data and setup files to internal non-volatile memory or to an external USB drive. Transfer data to a PC using the USB drive or LAN connection and view data in Microsoft® Excel
Data security: Administrator and user profiles for protecting settings and ensuring test traceability
Mx + B scaling and channel offset zero function
Alarms: Two independent, user-defined alarms for each channel indicate when an upper or lower range has been exceeded
Applications
Pharmaceutical
Biotechnology
Food processing
Aerospace
Automotive
Flexible configuration for the factory or bench-top
To simplify applications such as temperature uniformity testing, the Align Channels feature allows you to automatically “zero” offsets between sensors relative to a designated reference channel. An Mx + B offset is stored for each channel and an indicator let’s you know that an offset has been applied. Includes 20 math channels and 15 different mathematical operations that can be applied to measured results. Combining calculated results of multiple math channels lets you compute complex operations such as F0 calculations.
For a calibration lab where accuracy is of primary importance, the scanner is best configured with a DAQ-STAQ Multiplexer. The external DAQ-STAQ features mini-jack thermocouple terminals – each with its own reference junction sensor – and patented mini-DWF, gold-plated input terminals, which accept bare wire, spade lug, or mini-banana plug probe terminations. Easily connect and disconnect PRTs, thermistors, and thermocouples for bench-top temperature calibration. It can be stacked on the scanner to reduce footprint in busy labs. Having the flexibility to configure the scanner for factory or lab use reduces your equipment needs.
Multiple modes of operation
The scanner can operate in four modes that let you scan, monitor, measure, or function as a digital multimeter from a single instrument.
Sequentially scan through channels based on a user defined test. Depending on your application, select a fast, medium, or slow scan rate. With scan speeds as fast as 10 channels per second, you can collect data on all 40 channels in less than four seconds. Easily capture time-stamped measurements and correlate related events. Scans can be initiated through six different trigger types to include: external
trigger, time interval, remote SCPI command, alarm trigger, manual trigger, and an automated test trigger.
Monitor any single channel during a scan, without interrupting the scan. Measure and record data on a single channel without pre-configuring a test file. In DMM mode, use the front panel channel like a familiar bench-top digital multimeter to quickly measure dc voltage, dc current, or 2-wire and 4-wire resistance. Function keys are backlit so that you always know the mode of operation and recording status.
Real-time graphing in color
This scanner lets you view real-time data for all channels in table format or chart up to four channels in color at the same time. You can quickly see the current process state at-a-glance, or easily verify that your channels have been connected and configured properly.
You can zoom in or out to see data of interest and monitor trends. A history mode lets you scroll through collected data within a scan file – all without a PC and expensive software. Switch between chart view and table view to see measurement data and statistics, including average, standard deviation, minimum, maximum, peak-to-peak, and rate of change.
Not only does it include a rich graphical display, but you can also select between nine different languages including English, Chinese, French, German, Japanese, Korean, Portuguese, Spanish, or Russian.
Each channel can be assigned two independent alarms which indicate when either an upper HI) or lower LO) range has been exceeded. If an alarm trips, the out-of-range condition is indicated on the display. Alarms can also be assigned to any of the six TTL outputs for control of external devices.
Data portability and security
Includes 20 MB of internal memory that can store over 75,000 time-stamped readings. Data and setup files can be easily moved to a PC for
analysis using a USB flash drive or over a network using the LAN interface connection. It also includes two levels of data security to prevent unauthorized users from tampering with or forging test data or setup files. This security feature is especially important to industries that are regulated by government agencies where data traceability is required.
Automated sensor calibration
With the Automated Test feature, you can automate sensor calibration without a PC and software. When connected to a Fluke Calibration dry well or fluid bath via the RS-232 interface, the scanner takes control of the temperature source and runs your calibration automatically. You simply program the number of set-point temperatures and their values, select a scan sequence linear, alternate, up/down), assign a reference channel, and set the required stability band.
Monitors the temperature source’s stability via the reference channel, collects the data once stabilized, and then advances to the next set-point temperature. After you configure and start the test, you can walk away to work on other things. Fluke 1586A/1DS OffersCollects time-stamped precision temperature and electrical measurements for data analysis by technicians, engineers, and quality control personnel to verify process control, analyze interactive systems, ensure conformance to quality standards, or to correlate related events for R&D or troubleshooting. Measurement data and statistics can be viewed in tabular format for all active channels. With the graphing feature, up to four channels can be plotted at the same time, making it easy to quickly assess test setup and results before analyzing the data on a PC.
Features
Best temperature measurement accuracy
Flexible configuration for the factory or bench-top
Real-time graphing in color
Data portability and security
Automated sensor calibration
Measure thermocouples, PRTs, thermistors, DC voltage, DC current, and resistance
Input channels: Up to 40 isolated universal inputs
Selectable scan speed: Up to 10 channels per second
Four modes of operation: Scan, Monitor, Measure, Digital Multimeter DMM)
Real-time color trending: Chart up to four channels simultaneously
6 1/2 digit display resolution for DC voltage, DC current, and resistance
Current reversal minimizes thermoelectric effects, improving PRT/RTD measurement accuracy
Automated sensor calibration: Control Fluke Calibration temperature sources such as dry-wells or micro-baths for automated calibration routines
Data storage: Records up to 20 MB of data and setup files to internal non-volatile memory or to an external USB drive. Transfer data to a PC using the USB drive or LAN connection and view data in Microsoft® Excel
Data security: Administrator and user profiles for protecting settings and ensuring test traceability
Mx + B scaling and channel offset zero function
Alarms: Two independent, user-defined alarms for each channel indicate when an upper or lower range has been exceeded
Applications
Pharmaceutical
Biotechnology
Food processing
Aerospace
Automotive
Flexible configuration for the factory or bench-top
To simplify applications such as temperature uniformity testing, the Align Channels feature allows you to automatically “zero” offsets between sensors relative to a designated reference channel. An Mx + B offset is stored for each channel and an indicator let’s you know that an offset has been applied. Includes 20 math channels and 15 different mathematical operations that can be applied to measured results. Combining calculated results of multiple math channels lets you compute complex operations such as F0 calculations.
For a calibration lab where accuracy is of primary importance, the scanner is best configured with a DAQ-STAQ Multiplexer. The external DAQ-STAQ features mini-jack thermocouple terminals – each with its own reference junction sensor – and patented mini-DWF, gold-plated input terminals, which accept bare wire, spade lug, or mini-banana plug probe terminations. Easily connect and disconnect PRTs, thermistors, and thermocouples for bench-top temperature calibration. It can be stacked on the scanner to reduce footprint in busy labs. Having the flexibility to configure the scanner for factory or lab use reduces your equipment needs.
Multiple modes of operation
The scanner can operate in four modes that let you scan, monitor, measure, or function as a digital multimeter from a single instrument.
Sequentially scan through channels based on a user defined test. Depending on your application, select a fast, medium, or slow scan rate. With scan speeds as fast as 10 channels per second, you can collect data on all 40 channels in less than four seconds. Easily capture time-stamped measurements and correlate related events. Scans can be initiated through six different trigger types to include: external
trigger, time interval, remote SCPI command, alarm trigger, manual trigger, and an automated test trigger.
Monitor any single channel during a scan, without interrupting the scan. Measure and record data on a single channel without pre-configuring a test file. In DMM mode, use the front panel channel like a familiar bench-top digital multimeter to quickly measure dc voltage, dc current, or 2-wire and 4-wire resistance. Function keys are backlit so that you always know the mode of operation and recording status.
Real-time graphing in color
This scanner lets you view real-time data for all channels in table format or chart up to four channels in color at the same time. You can quickly see the current process state at-a-glance, or easily verify that your channels have been connected and configured properly.
You can zoom in or out to see data of interest and monitor trends. A history mode lets you scroll through collected data within a scan file – all without a PC and expensive software. Switch between chart view and table view to see measurement data and statistics, including average, standard deviation, minimum, maximum, peak-to-peak, and rate of change.
Not only does it include a rich graphical display, but you can also select between nine different languages including English, Chinese, French, German, Japanese, Korean, Portuguese, Spanish, or Russian.
Each channel can be assigned two independent alarms which indicate when either an upper HI) or lower LO) range has been exceeded. If an alarm trips, the out-of-range condition is indicated on the display. Alarms can also be assigned to any of the six TTL outputs for control of external devices.
Data portability and security
Includes 20 MB of internal memory that can store over 75,000 time-stamped readings. Data and setup files can be easily moved to a PC for
analysis using a USB flash drive or over a network using the LAN interface connection. It also includes two levels of data security to prevent unauthorized users from tampering with or forging test data or setup files. This security feature is especially important to industries that are regulated by government agencies where data traceability is required.
Automated sensor calibration
With the Automated Test feature, you can automate sensor calibration without a PC and software. When connected to a Fluke Calibration dry well or fluid bath via the RS-232 interface, the scanner takes control of the temperature source and runs your calibration automatically. You simply program the number of set-point temperatures and their values, select a scan sequence linear, alternate, up/down), assign a reference channel, and set the required stability band.
Monitors the temperature source’s stability via the reference channel, collects the data once stabilized, and then advances to the next set-point temperature. After you configure and start the test, you can walk away to work on other things.
Fluke 1586A/1DS Specifications
PRT/RTD 100 Ω Nominal)
Temperature Range
-200 to 1200°C depending on the sensor)
Temperature Resolution
0.001°C
Temperature Accuracy
0.005°C at -200°C
0.005°C at 0°C
0.012°C at 300°C
Resistance Accuracy
0.002% or 0.008 Ω
Excitation Current
1 mA with current reversal
Thermistor 10 KΩ Nominal)
Temperature Range
-200 to 400°C depending on the sensor)
Temperature Resolution
0.0001°C
Temperature Accuracy
0.002°C at 0°C
0.009°C at 50°C
0.024°C at 100°C
Resistance Accuracy
0.004% + 0.5 Ω
Excitation Current
10 μA
Thermocouple Type K
Temperature Range
-270 to 1372°C
Temperature Resolution
0.01°C/td>
Temperature Accuracy int CJC)
0.29°C at 0°C
0.32°C at 1000°C
Temperature Accuracy ext CJC)
0.15°C at 0°C
0.20°C at 1000°C
Voltage Accuracy
0.004% + 4 μV ch. 1
0.004% + 6 μV ch. x01-x20
Thermocouple Type T
Temperature Range
-270 to 400°C
Temperature Resolution
0.01°C
Temperature Accuracy int CJC)
0.30°C at 0°C
0.23°C at 200°C
Temperature Accuracy ext CJC)
0.15°C at 0°C
0.12°C at 200°C
Voltage Accuracy
0.004% + 4 μV ch. 1
0.004% + 6 μV ch. x01-x20
Thermocouple Type S
Temperature Range
-50 to 1768°C
Temperature Resolution
0.01°C
Temperature Accuracy int CJC)
0.68°C at 300°C
0.55°C at 1200°C
Temperature Accuracy ext CJC)
0.67°C at 300°C
0.54°C at 1200°C
Voltage Accuracy
0.004% + 4 μV ch. 1
0.004% + 6 μV ch. x01-x20
DC Voltage Medium or Slow Sample Rate)
Range
±100 mV
±50 V
Accuracy Channel 1
0.0037% + 0.0035%
0.0038% + 0.0012%
Ch. X01 – x202
Add 2 μV
Fast Sample Rate
Add 0.0008% of range
Resolution
0.1 μV
1 mV
Input Impedance
10 GΩ [1]
10 MΩ ±1%
DC Current Medium or Slow Sample Rate)
Range
±100 μA
±10 mA
±100 mA
Accuracy
0.015% + 0.0035%
Fast Sample Rate
Add 0.0008% of range
Resolution
0.1 nA
10 nA
100 nA
Burden Voltage
<1 mV
Resistance Medium or Slow Sample Rate, 4-Wire Resistance)
Range
100 Ω
10 kΩ
10 MΩ
Accuracy
0.004% + 0.0035%
0.004% + 0.001%
0.015% + 0.001%
Fast Sample Rate
Add 0.001% of range
Add 0.01% of range
Resolution
0.1 mΩ
10 mΩ
1 kΩ
Source Current
1 mA
100 μA
0.1 μA
General Specifications
Channel Capacity
Total analog channels: 45
Voltage/resistance channels: 41
Current channels: 5
Digital I/O: 1 8-bit TTL)
Totalizer: 1
Alarm outputs: 6
Trigger input: 1
Sample Rate
Fast: 10 channels per second 0.1 seconds per channel)
Medium: 1 channel per second 1 second per channel)
Slow: 4 seconds per channel
Display Resolution
6 1/2 digits
Input Module Options
2 rear panel slots 'x' designates slot 1 or slot 2 below)
Internal High-Capacity Module configuration
20 channels per module x01 - x20)
2 dedicated current channels x21 - x22)
3- and 4-wire connections require 2 channels)
Math Channels
20 channels
Operations: sum, difference, multiply, divide, polynomial, power, square root, reciprocal, exponential, logarithm, absolute value, average, maximum, minimum
Triggers
Interval, external trigger input), alarm, remote bus), manual, automated test
Memory
Scan data RAM: 75,000 readings with timestamp
Internal memory: 20 MB
Standard Interfaces
USB host, USB device, Ethernet 10/100 LAN, RS-232 temperature source control for automated temperature data collection from Fluke Calibration drywells and baths
Mains Voltage
100 V setting: 90 to 100 V
120 V setting: 108 to 132 V
220 V setting: 198 to 242 V
240 V setting: 216 to 264 V
Mains Frequency
47 to 440 Hz
Input Protection
50 V all functions, terminals and ranges
Dimensions
5.9 x 9.6 x 15.2" 150 x 245 x 385 mm)
Weight
13.2 lbs 6 kg)
Conformity
CE, CSA, IEC 61010 3rd edition
Click here for complete specifications on the Fluke 1586A/1DS
What's included with the Fluke 1586A/1DS
Scanner
DAQ-STAQ Multiplexer
Additional information
Weight | 6 kg |
---|---|
Dimensions | 15 × 24.5 × 38.5 cm |
Model | 1586A/1DS |
PRODUCT TYPE | Thermometers |
Brand | FLUKE |
Warranty | 12Months Warranty against manufacturers defects |
Country of Origin | USA |
Related Products
Ships in 5 -10days
Ships in 5 -10days
Ships in 5 -10days
Ships in 5 -10days
Ships in 5 -10days
Ships in 5 -10days
Ships in 5 -10days
Ships in 5 -10days
Ships in 5 -10days
Ships in 5 -10days
Ships in 5 -10days
Ships in 5 -10days